Publications by Year: 2013

2013
Moraitou MD, Latsas GP, Ioannidis ZC, Tigelis IG. Parasitic Oscillations in Coaxial Gyrotron Beam Tunnels. {IEEE} Transactions on Electron Devices [Internet]. 2013;60:1469–1475. Website
Pagonakis IG, Gantenbein G, Jelonnek J, Jin J, Illy S, Kern S, Piosczyk B, Rzesnicki T, Thumm M, Avramides KA, et al. Design of the EU-1MW gyrotron for ITER. In: Vacuum Electronics Conference (IVEC), 2013 IEEE 14th International. ; 2013. pp. 1-2.Abstract
EU is developing a 1 MW cylindrical cavity gyrotron. In the last year the design of the components of the new gyrotron has been finalized while the technological design of the new tube has been defined. In the present paper, the main characteristics of the new EU gyrotron for ITER are presented.
Moraitou MD, Latsas GP, Ioannidis ZC, Tigelis IG. Parasitic Oscillations in Coaxial Gyrotron Beam Tunnels. Electron Devices, IEEE Transactions on. 2013;60:1469-1475.Abstract
High-power high-frequency gyrotrons are required for several applications, including plasma heating, current drive, and plasmas stabilization for controlled thermonuclear fusion. Despite the use of dumping dielectric material in these gyrotrons, parasitic oscillations often appear, which significantly affect their operation and efficiency. In this paper, we perform an extended parametric study on the effect of the beam-tunnel characteristics, i.e., the outer radius of the inner waveguide and the width of the grooves, as well as the lossy material properties and the beam-radial position on the dumping of these oscillations.